Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Eur J Radiol ; 85(3): 665-72, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26860682

RESUMO

PURPOSE: To assess the effect of a noise-optimized image-based virtual monoenergetic imaging (VMI+) algorithm in direct comparison with the traditional VMI technique and standard linearly-blended images emulating 120-kVp acquisition (M_0.3) on image quality at dual-energy CT in patients with lung cancer. MATERIALS AND METHODS: Dual-source dual-energy CT examinations of 48 patients with biopsy-proven primary (n=31) or recurrent (n=20) lung cancer were evaluated. Images were reconstructed as M_0.3, and VMI+ and traditional VMI series at 40, 55, and 70keV. Attenuation of tumor, descending aorta, pulmonary trunk, latissimus muscle, and noise were measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used by three observers to subjectively evaluate general image impression, tumor delineation, image sharpness, and image noise. RESULTS: Background noise was consistently lower with VMI+ compared to VMI at all keV levels (all p<0.0001) and M_0.3 (all p≤0.0004). Tumor SNR and CNR peaked in the 40keV VMI+ series, significantly higher compared to all VMI and M_0.3 series (all p<0.0008). Observers preferred the 55keV VMI+ series regarding general image impression and tumor delineation compared to all other series (all p<0.0001). Image sharpness and image noise ratings were highest in the 55keV VMI+ and 70keV VMI and VMI+ reconstructions. CONCLUSIONS: Tumor CNR peaked at 40keV VMI+ while observers preferred 55keV VMI+ series overall other series for dual-energy CT of lung cancer. The noise-optimized VMI+ technique showed significantly lower background noise and higher SNR and CNR compared to the traditional VMI technique at matching keV levels.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Ruído , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
2.
Acad Radiol ; 23(3): 267-72, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26749327

RESUMO

RATIONALE AND OBJECTIVES: This investigation aimed to evaluate the impact on treatment regimen and clinical outcome of dual-energy computed tomography (DECT) in patients with suspected gouty arthritis. MATERIALS AND METHODS: We retrospectively analyzed electronic medical records (EMR) of 39 patients (36 male, 3 female; age range, 36-85 years) who underwent DECT of peripheral joints because of suspected gouty arthritis. We assessed the prior medical history, lab results, treatment regimen, and medications before and after DECT, and changes in subjective severity of symptoms as stated by patients in the EMR. The presence of monosodium urate (MSU) crystals in the index joint was verified with DECT. RESULTS: Several patients had a prior diagnosis of gout (n = 9), hyperuricemia (n = 6), rheumatoid arthritis (n = 3), or psoriatic arthritis (n = 3). Elevated uric acid blood levels were detected in 32 patients (82%) before DECT. On DECT, MSU crystals were detected in 23 patients (59%). Of the 36 cases, the current treatment regimen was modified after DECT to gout-specific therapy in 22 cases and other rheumatic diseases were targeted in 14 cases. Several medications were prescribed more frequently based after DECT compared to before DECT imaging, including steroids (n = 20 vs. n = 12, respectively), colchicine (n = 13 vs. n = 4, respectively), and urate-lowering medication (n = 18 vs. n = 11, respectively). A subjective reduction of clinical symptoms during cumulative follow-up was reported by 34 patients (87.2%). CONCLUSIONS: Both positive and negative findings of MSU crystals on DECT have a significant impact on the treatment regimen and clinical outcome of patients with suspected gouty arthritis and facilitate differentiation from other rheumatic diseases.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Corticosteroides/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/uso terapêutico , Artrite Gotosa/sangue , Artrite Gotosa/tratamento farmacológico , Artrite Psoriásica/diagnóstico , Artrite Reumatoide/diagnóstico , Colchicina/uso terapêutico , Registros Eletrônicos de Saúde , Feminino , Seguimentos , Gota/diagnóstico , Supressores da Gota/uso terapêutico , Humanos , Hiperuricemia/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ácido Úrico/sangue , Ácido Úrico/química
3.
J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Eur J Radiol ; 84(11): 2052-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26220917

RESUMO

PURPOSE: To evaluate a novel monoenergetic reconstruction algorithm (nMERA) with improved noise reduction for dual-energy CT (DECT) of pancreatic adenocarcinoma. MATERIALS AND METHODS: Sixty patients with suspected pancreatic carcinoma underwent dual-source dual-energy CT with arterial phase. Images were reconstructed as linearly-blended 120-kV series (M_0.6) and with the standard monoenergetic (sMERA) and the novel monoenergetic algorithm (nMERA) with photon energies of 40, 55, 70 and 80 keV. Objective image quality was compared regarding image noise, pancreas attenuation, signal-to-noise ratio (SNR) and pancreas-to-lesion contrast. Subjective image quality was assessed by two observers. RESULTS: Thirty pancreatic adenocarcinomas were detected. nMERA showed significantly reduced image noise at low keV levels compared with sMERA images (55 keV: 7.19 ± 2.75 vs. 20.68 ± 7.01 HU; 40 keV: 7.33 ± 3.20 vs. 37.22 ± 14.66 HU) and M_0.6 (10.69 ± 3.57 HU). nMERA pancreatic SNR was significantly superior to standard monoenergetic at 40 (47.02 ± 23.41 vs. 9.37 ± 5.83) and 55 keV (28.29 ± 16.86 vs. 9.88 ± 7.01), and M_0.6 series (11.42 ± 6.00). Pancreas-to-lesion contrast peaked in the nMERA 40 keV series (26.39 ± 16.83) and was significantly higher than in all other series (p<0.001). nMERA 55 keV images series were consistently preferred by both observers over all other series (p<0.01). CONCLUSIONS: nMERA DECT can significantly improve image quality and pancreas-to-lesion contrast in the diagnosis of pancreatic adenocarcinoma.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Estudos Retrospectivos , Neoplasias Pancreáticas
5.
Eur J Radiol ; 84(10): 1910-4, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26104571

RESUMO

PURPOSE: To investigate the association between aortic root calcification (ARC) and coronary artery calcification (CAC) assessed by coronary artery calcium-scoring dual-source computed tomography (DSCT). MATERIALS AND METHODS: We retrospectively analyzed 143 consecutive patients who underwent coronary artery calcium-scoring during coronary DSCT angiography. 57 patients had findings of ARC on calcium-scoring scans. ARC volume (ARCV) and Agatston coronary artery calcium score (CACS) were calculated. Chi-square test was used to assess differences of categorical variables between patients with and without ARC. Statistical significances between both groups were assessed with the independent-Sample t test. RESULTS: Compared with patients without ARC (n=86), patients with ARC (n=57) showed a significantly higher presence of CAC (87.7% vs. 24.4%; P<0.001), and a higher mean CACS (700.6 ± 941.2 vs. 256.4 ± 724.3; P=0.009) in patients with CAC. Patients with a calculated ARCV > 40 mm(3) (n=32) showed significantly higher rates of severe CAC (56.3% vs. 24.0%; P=0.014) compared with patients with an ARCV< 40 mm(3) (n=25). Compared with patients without CAC (n=42), patients with CAC (n=101) showed a significantly higher presence of ARC (83.3% vs. 50.5%; P<0.001) and a higher mean ARCV (95.4 ± 116.2mm(3) vs. 29.7 ± 33.0 mm(3); P=0.003). Severe CAC (n=24) correlated with an increased mean ARCV (122.3 ± 148.8mm(3)) compared to patients with minimal to moderate CAC (n=33, mean ARCV: 61.9 ± 64.8mm(3); P<0.05). CONCLUSIONS: The extent of ARC is directly associated with the presence and degree of CAC on calcium-scoring scans during coronary DSCT angiography.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Cálcio/análise , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Calcificação Vascular/diagnóstico por imagem , Idoso , Doenças da Aorta/complicações , Aortografia/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Calcificação Vascular/complicações
6.
Radiol Med ; 120(12): 1112-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981379

RESUMO

OBJECTIVES: To compare radiation exposure and image quality of second-generation 128-slice dual-source CT (DSCT) coronary angiography (cCTA) protocols. MATERIALS AND METHODS: We retrospectively analyzed data from four groups with 25 patients, each examined by one of the following DSCT cCTA protocols: prospectively ECG-gated high-pitch (group 1) or sequential (group 2) acquisition, retrospectively ECG-gated acquisition in dual-energy (DECT, group 3) or dual-source (group 4) mode. CT dose index volume, dose length product, estimated radiation dose, contrast-to-noise- and signal-to-noise-ratios were compared. Subjective image quality was rated by two observers blinded to the protocols. RESULTS: High-pitch DSCT showed a mean estimated radiation dose of 1.27 ± 0.62 mSv, significantly (p < 0.01) lower than sequential (2.04 ± 0.94 mSv), dual-energy (3.97 ± 1.29 mSv) or dual-source (8.11 ± 4.95 mSv) acquisition. Image noise showed no statistical difference (p > 0.91), ranging from 15.2 ± 4.4 (group 2) up to 24.5 ± 22.0 (group 4). Each protocol showed diagnostic image quality in at least 98.1 % of evaluated coronary segments without significant differences (p > 0.05). CONCLUSIONS: Prospectively ECG-gated DSCT protocols enable cCTA with significant dose reduction and consistently diagnostic image quality. In patients requiring retrospectively ECG-gated DSCT for functional analysis or due to arrhythmia, dual-energy mode should be preferred over dual-source mode as it significantly decreases estimated dose without compromising image quality.


Assuntos
Angiografia Coronária/métodos , Aumento da Imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Estudos Retrospectivos
7.
Neuroradiology ; 57(6): 645-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25808122

RESUMO

INTRODUCTION: To investigate low-tube-voltage 80-kVp computed tomography (CT) of head and neck primary and recurrent squamous cell carcinoma (SCC) regarding objective and subjective image quality. METHODS: We retrospectively evaluated 65 patients (47 male, 18 female; mean age: 62.1 years) who underwent head and neck dual-energy CT (DECT) due to biopsy-proven primary (n = 50) or recurrent (n = 15) SCC. Eighty peak kilovoltage and standard blended 120-kVp images were compared. Attenuation and noise of malignancy and various soft tissue structures were measured. Tumor signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was rated by three reviewers using 5-point grading scales regarding overall image quality, lesion delineation, image sharpness, and image noise. Radiation dose was assessed as CT dose index volume (CTDIvol). Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Mean tumor attenuation (153.8 Hounsfield unit (HU) vs. 97.1 HU), SNR (10.7 vs. 8.3), CNR (8.1 vs. 4.8), and subjective tumor delineation (score, 4.46 vs. 4.13) were significantly increased (all P < 0.001) with 80-kVp acquisition compared to standard blended 120-kVp images. Noise of all measured structures was increased in 80-kVp acquisition (P < 0.001). Overall interobserver agreement was good (ICC, 0.86; 95 % confidence intervals: 0.82-0.89). CTDIvol was reduced by 48.7 % with 80-kVp acquisition compared to standard DECT (4.85 ± 0.51 vs. 9.94 ± 0.81 mGy cm, P < 0.001). CONCLUSIONS: Head and neck CT with low-tube-voltage 80-kVp acquisition provides increased tumor delineation, SNR, and CNR for CT imaging of primary and recurrent SCC compared to standard 120-kVp acquisition with an accompanying significant reduction of radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
8.
Radiol Med ; 120(7): 595-602, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25644250

RESUMO

PURPOSE: This study was done to investigate the dynamic changes of the aortic root during systole and diastole in patients with coronary artery calcification (CAC) using dual-source computed tomography (DSCT). MATERIALS AND METHODS: We retrospectively analysed 77 consecutive patients who underwent calcium-scoring and angiographic cardiac DSCT. The long- and short-axis dimensions, axis areas of the aortic annulus, sinotubular junction and ascending aorta at the level of the pulmonary trunk in diastole and systole were measured. Average dimensions and relative areal changes between diastole and systole (%RA) of aortic annulus, sinotubular junction and ascending aorta were compared. RESULTS: Systolic and diastolic long- and short-axis dimensions of the aortic annulus in patients with CAC (n = 44) demonstrated statistically significant differences (27.00 ± 2.84 mm vs. 28.04 ± 2.62 mm; P < 0.001; 21.78 ± 2.55 mm vs. 20.88 ± 2.31 mm; P < 0.001), while differences in average diameters and areas of the aortic annulus were nonsignificant (P > 0.586). Systolic and diastolic axial areas of the sinotubular junction in patients with CAC demonstrated significant differences (7.21 ± 1.80 cm(2) vs. 6.92 ± 1.75 cm(2); P < 0.001). The %RA of the ascending aorta in patients with severe CAC (CAC score >400; n = 15) was significantly reduced compared to patients with minimal-to-moderate CAC (CAC score <400; n = 29; 4.77 ± 2.88 vs. 7.51 ± 3.81, P = 0.014). CONCLUSIONS: In comparison with patients without CAC, the long- and short-axis dimensions of the aortic annulus and areas of the sinotubular junction show significant differences during the cardiac cycle in patients with CAC. The presence of severe CAC significantly influences the flexibility of the wall of the ascending aorta.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Diástole , Sístole , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Eur Radiol ; 25(8): 2493-501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680727

RESUMO

OBJECTIVES: To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS: DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS: The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS: Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS: • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
10.
Eur J Radiol ; 84(3): 437-442, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25554009

RESUMO

OBJECTIVES: To evaluate software for automatic segmentation, labeling and reformation of anatomical aligned axial images of the thoracolumbar spine on CT in terms of accuracy, potential for time savings and workflow improvement. MATERIAL AND METHODS: 77 patients (28 women, 49 men, mean age 65.3±14.4 years) with known or suspected spinal disorders (degenerative spine disease n=32; disc herniation n=36; traumatic vertebral fractures n=9) underwent 64-slice MDCT with thin-slab reconstruction. Time for automatic labeling of the thoracolumbar spine and reconstruction of double-angulated axial images of the pathological vertebrae was compared with manually performed reconstruction of anatomical aligned axial images. Reformatted images of both reconstruction methods were assessed by two observers regarding accuracy of symmetric depiction of anatomical structures. RESULTS: In 33 cases double-angulated axial images were created in 1 vertebra, in 28 cases in 2 vertebrae and in 16 cases in 3 vertebrae. Correct automatic labeling was achieved in 72 of 77 patients (93.5%). Errors could be manually corrected in 4 cases. Automatic labeling required 1min in average. In cases where anatomical aligned axial images of 1 vertebra were created, reconstructions made by hand were significantly faster (p<0.05). Automatic reconstruction was time-saving in cases of 2 and more vertebrae (p<0.05). Both reconstruction methods revealed good image quality with excellent inter-observer agreement. CONCLUSION: The evaluated software for automatic labeling and anatomically aligned, double-angulated axial image reconstruction of the thoracolumbar spine on CT is time-saving when reconstructions of 2 and more vertebrae are performed. Checking results of automatic labeling is necessary to prevent errors in labeling.


Assuntos
Radiografia Torácica , Fraturas da Coluna Vertebral/diagnóstico por imagem , Parede Torácica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Fraturas da Coluna Vertebral/patologia , Parede Torácica/patologia , Tomografia Computadorizada por Raios X/métodos
11.
Eur J Radiol ; 84(1): 117-122, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25467230

RESUMO

OBJECTIVES: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. MATERIALS AND METHODS: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. RESULTS: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power. CONCLUSIONS: Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units.


Assuntos
Eficiência Organizacional/estatística & dados numéricos , Serviço Hospitalar de Emergência/organização & administração , Traumatismo Múltiplo/diagnóstico por imagem , Pacientes/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Fluxo de Trabalho , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Pacientes Internados , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Adulto Jovem
12.
Eur Radiol ; 25(6): 1714-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25481639

RESUMO

OBJECTIVES: To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. METHODS: Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. RESULTS: Average pedicle screw vector BMD (R1, 0.232 g/cm(3); R2, 0.166 g/cm(3); R3, 0.173 g/cm(3); global, 0.236 g/cm(3)) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. CONCLUSIONS: Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. KEY POINTS: • Quantitative dual-energy CT enables evaluation of pedicle bone mineral density. • Intrapedicular segments show significant differences regarding bone mineral density. • Pedicle screw pull-out strength correlated strongest with R1 values. • Dual-energy CT may improve preoperative assessment before transpedicular screw fixation.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/fisiologia , Parafusos Pediculares , Vértebras Torácicas/fisiologia , Absorciometria de Fóton/métodos , Idoso , Fenômenos Biomecânicos , Cadáver , Estudos de Casos e Controles , Remoção de Dispositivo , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
13.
Eur Radiol ; 24(11): 2927-35, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25030462

RESUMO

OBJECTIVES: To intra-individually compare single-portal-phase low-tube-voltage (100-kVp) computed tomography (CT) with 120-kVp images for short-term follow-up assessment of CT severity index (CTSI) of acute pancreatitis, interobserver agreement and radiation dose. METHODS: We retrospectively analysed 66 patients with acute pancreatitis who underwent initial dual-contrast-phase CT (unenhanced, arterial, portal phase) at admission and short-term (mean interval 11.4 days) follow-up dual-contrast-phase dual-energy CT. The 100-kVp and linearly blended images representing 120-kVp acquisition follow-up CT images were independently evaluated by three radiologists using a modified CTSI assessing pancreatic inflammation, necrosis and extrapancreatic complications. Scores were compared with paired t test and interobserver agreement was evaluated using intraclass correlation coefficients (ICC). RESULTS: Mean CTSI scores on unenhanced, portal- and dual-contrast-phase images were 4.9, 6.1 and 6.2 (120 kVp) and 5.0, 6.0 and 6.1 (100 kVp), respectively. Contrast-enhanced series showed a higher CTSI compared to unenhanced images (P < 0.05) but no significant differences between single- and dual-contrast-phase series (P > 0.7). CTSI scores were comparable for 100-kVp and 120-kVp images (P > 0.05). Interobserver agreement was substantial for all evaluated series and subcategories (ICC 0.67-0.93). DLP of single-portal-phase 100-kVp images was reduced by 41 % compared to 120-kVp images (363.8 versus 615.9 mGy cm). CONCLUSIONS: Low-tube-voltage single-phase 100-kVp CT provides sufficient information for follow-up evaluation of acute pancreatitis and significantly reduces radiation exposure. KEY POINTS: • Single-portal-phase CT provides sufficient evaluation for follow-up of acute pancreatitis. • Follow-up CT does not benefit from unenhanced or arterial-phase acquisition. • CT severity index scores are equal for dual-contrast-phase 100-/120-kVp acquisition (P > 0.05). • 100-kVp single-portal-phase follow-up CT of acute pancreatitis significantly reduces radiation exposure.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Pancreatite Necrosante Aguda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Adulto Jovem
14.
Int J Cardiovasc Imaging ; 30(6): 1145-50, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24810781

RESUMO

To compare non-linear and linear blending of cardiac dual-energy computed tomography (DECT) for optimal visualization of late iodine enhancement (LIE) in patients with chronic myocardial infarction (CMI). LIE-DECT data from 20 patients with known CMI were retrospectively analyzed. Images were reconstructed using non-linear blending center and width settings in the range of 0-500. Linear blending was performed with weighting factors 0.8 (80% 100 kV, 20% 140 kV), 0.6 and 0.3. 100-/140-kV data and blended images were analyzed. Contrast and percentage signal differences between infarcted and healthy myocardium and the left ventricle blood pool were computed. Statistical analysis was performed using repeated-measures analysis of variance and post hoc t tests. Non-linear blending showed the highest signal differences for all contrasts and analyses. Repeated-measures ANOVA tests confirmed the statistical differences between the investigated blending techniques (P < 0.01). Paired-samples post hoc t tests confirmed the significance of these results (P < 0.04). The ideal non-linear blending settings for best demarcation of CMI from healthy myocardium were a center of 65.8 ± 23.2 and a width of 0.0 ± 0.0. Non-linear blending of LIE-DECT improves display of LIE in patients with CMI in comparison with linear blending and non-post-processed image data from 100-/140-kV.


Assuntos
Meios de Contraste , Iopamidol/análogos & derivados , Infarto do Miocárdio/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Dinâmica não Linear , Valor Preditivo dos Testes , Estudos Retrospectivos
15.
Invest Radiol ; 49(11): 735-41, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24872006

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effects on objective and subjective image quality of virtual monoenergetic reconstructions at various energy levels of dual-energy computed tomography (DECT) in patients with head and neck cancer. MATERIALS AND METHODS: We included 71 (53 men, 18 women; age, 59.3 ± 12.0 years; range, 33-90 years) patients with biopsy-proven untreated primary (n = 55) or recurrent (n = 16) squamous cell carcinoma who underwent head and neck DECT. Images were reconstructed with a linear blending setting emulating 120 kV acquisition (M_0.3; 30% of 80 kV, 70% of 140 kV spectrum) and as virtual monoenergetic images with photon energies of 40, 60, 80, and 100 keV. Attenuation of lesion, various anatomic landmarks, and image noise were objectively measured, and lesion contrast-to-noise ratio (CNR) was calculated. Two independent blinded radiologists subjectively rated each image series using a 5-point grading scale regarding overall image quality, lesion delineation, image sharpness, and image noise. RESULTS: Tumor attenuation peaked at 40 keV (140.2 ± 42.6 HU) followed by the 60 keV (121.7 ± 25.5 HU) and M_0.3 series (102.7 ± 22.3; all P < 0.001). However, the calculated lesion CNR was highest in the 60 keV reconstructions (12.45 ± 7.17), 80 keV reconstructions (8.66 ± 6.58), and M_0.3 series (5.21 ± 3.15; all P < 0.001) and superior to the other monoenergetic series (all P < 0.001). Subjective image analysis was highest for the 60 keV series regarding overall image quality (4.22; κ = 0.411) and lesion delineation (4.35; κ = 0.459) followed by the M_0.3 series (3.81; κ = 0.394; 3.77; κ = 0.451; all P < 0.001). Image sharpness showed no significant difference between both series (3.81 vs 3.79; P = 0.78). Image noise was rated superior in the 80 and 100 keV series (4.31 vs 4.34; P = 0.522). CONCLUSIONS: Compared with linearly blended images, virtual monoenergetic reconstructions of DECT data at 60 keV significantly improve lesion enhancement and CNR, subjective overall image quality, and tumor delineation of head and neck squamous cell carcinoma.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador/métodos , Iopamidol , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído , Interface Usuário-Computador
16.
Eur Radiol ; 24(7): 1725-34, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24816940

RESUMO

OBJECTIVE: To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. METHODS: One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modulation only. Another 100 patients underwent 128-slice CT with automated mA modulation and topogram-based automated tube potential selection (autokV) at 100, 120 or 140 kV. Volume CT dose index (CTDI(vol)), dose-length product (DLP), body diameters, noise, signal-to-noise ratio (SNR) and subjective image quality were compared. RESULTS: In the autokV group, 100 kV was automatically selected in 82 patients, 120 kV in 12 patients and 140 kV in 6 patients. Patient diameters increased with higher kV settings. The median CTDI(vol) (8.3 vs. 12.4 mGy; -33%) and DLP (594 vs. 909 mGy cm; -35%) in the entire autokV group were significantly lower than in the group with fixed 120 kV (p < 0.05 for both). Image quality remained at a constantly high level at any selected kV level. CONCLUSION: Topogram-based automated selection of the tube potential allows for significant dose savings in thoraco-abdominal trauma CT while image quality remains at a constantly high level. KEY POINTS: • Automated kV selection in thoraco-abdominal trauma CT results in significant dose savings • Most patients benefit from a 100-kV protocol with relevant DLP reduction • Constantly good image quality is ensured • Image quality benefits from higher kV when arms are positioned downward.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Multidetectores/instrumentação , Traumatismo Múltiplo/diagnóstico por imagem , Traumatismos Torácicos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
17.
Eur Radiol ; 24(6): 1211-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24599623

RESUMO

OBJECTIVES: To evaluate image quality and diagnostic accuracy of selective monoenergetic reconstructions of late iodine enhancement (LIE) dual-energy computed tomography (DECT) for imaging of chronic myocardial infarction (CMI). METHODS: Twenty patients with a history of coronary bypass surgery underwent cardiac LIE-DECT and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). LIE-DECT images were reconstructed as selective monoenergetic spectral images with photon energies of 40, 60, 80, and 100 keV and the standard linear blending setting (M_0.6). Images were assessed for late enhancement, transmural extent, signal characteristics and subjective image quality. RESULTS: Seventy-nine myocardial segments (23 %) showed LGE. LIE-DECT detected 76 lesions. Images obtained at 80 keV and M_0.6 showed a high signal-to-noise ratio (15.9; 15.1), contrast-to-noise ratio (4.2; 4.0) and sensitivity (94.9 %; 92.4 %) while specificity was identical (99.6 %). Differences between these series were not statistically significant. Transmural extent of LIE was overestimated in both series (80 keV: 40 %; M_0.6: 35 %) in comparison to MRI. However, observers preferred 80 keV in 13/20 cases (65 %, κ = 0.634) over M_0.6 (4/20 cases) regarding subjective image quality. CONCLUSIONS: Post-processing of LIE-DECT data with selective monoenergetic reconstructions at 80 keV significantly improves subjective image quality while objective image quality shows no significant difference compared to standard linear blending. KEY POINTS: Late enhancement dual-energy CT allows for detection of chronic myocardial infarction. Monoenergetic reconstructions at 80 keV significantly improve subjective image quality. 80 keV and standard linear blending reconstructions show no significant differences. Extent of CMI detected with LIE-DECT is overestimated compared with MRI.


Assuntos
Aumento da Imagem/métodos , Iodo , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Doença Crônica , Meios de Contraste , Ponte de Artéria Coronária , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
18.
Radiology ; 271(3): 778-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24475863

RESUMO

PURPOSE: To evaluate the feasibility of phantomless in vivo dual-energy computed tomography (CT)-based three-dimensional (3D) bone mineral density (BMD) assessment in comparison with dual x-ray absorptiometry (DXA). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. Data from clinically indicated dual-energy CT and DXA examinations within 2 months, comprising the lumbar spine of 40 patients, were included. By using automated dedicated postprocessing dual-energy CT software, the trabecular bone of lumbar vertebrae L1-L4 were analyzed and segmented. A mixed-effects model was used to assess the correlations between BMD values derived from dual-energy CT and DXA. RESULTS: One hundred sixty lumbar vertebrae were analyzed in 40 patients (mean age, 57.1 years; range, 24-85 years), 21 male (mean age, 54.3 years; range, 24-85 years) and 19 female (mean age, 58.5 years; range, 31-80 years). Mean BMD of L1-L4 determined with DXA was 0.995 g/cm(2), and 18 patients (45%) showed an osteoporotic BMD (T score less than -2.5) of at least two vertebrae. Mean dual-energy CT-based BMD of L1-L4 was 0.254 g/cm(3). Bland-Altman analysis with mixed effects demonstrated a lack of correlation between dual-energy CT-based and DXA-based BMD values, with a mean difference of 0.7441 and 95% limits of agreement of 0.7441 ± 0.4080. CONCLUSION: Dedicated postprocessing of dual-energy CT data allows for phantomless in vivo BMD assessment of the trabecular bone of lumbar vertebrae and enables freely rotatable color-coded 3D visualization of intravertebral BMD distribution.


Assuntos
Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Ósseas Metabólicas/patologia , Feminino , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Osteoporose/patologia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
19.
Eur Radiol ; 24(3): 574-80, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24081649

RESUMO

OBJECTIVES: To evaluate whether dual-energy computed tomography (DECT)-derived iodine content and iodine overlay could differentiate between normal, inflammatory and metastatic squamous cell carcinoma (SCC) cervical lymph nodes. METHODS: This study was approved by the institutional review board. Sixteen patients with normal lymph nodes, 20 patients with enlarged nodes draining deep cervical inflammations and 23 patients with pathologically proved metastatic SCC nodes who underwent contrast enhanced DECT were retrospectively identified. Iodine content and overlay of 36 normal, 43 inflammatory and 52 metastatic lymph nodes were calculated using circular regions of interest and compared among the three groups. A receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of iodine content and overlay for diagnosis of metastatic nodes. RESULTS: Iodine content (mg/ml) was significantly lower for metastatic lymph nodes (2.34 ± 0.45) than for normal (2.86 ± 0.37) and inflammatory (3.53 ± 0.56) lymph nodes, P < 0.0001. Iodine overlay (HU) was also significantly lower for metastatic lymph nodes (47 ± 11.6) than normal (57.4 ± 8.2) and inflammatory nodes (69.3 ± 11.5), P < 0.0001. The areas under the ROC curve for iodine content and iodine overlay were 0.923 and 0.896. CONCLUSIONS: DECT-derived iodine content and overlay differ significantly among normal, inflammatory and metastatic SCC cervical lymph nodes. KEY POINTS: • Derived iodine content can be calculated from contrast-enhanced dual-energy CT. • Derived iodine content and iodine overlay could help characterise cervical lymph nodes. • Iodine parameters were significantly lower in metastatic lymph nodes than normal/inflammatory lymph nodes. • Iodine content appears more sensitive than iodine overlay for lymph node characterisation.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Iodo/metabolismo , Linfadenite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/secundário , Feminino , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/metabolismo , Linfadenite/metabolismo , Linfadenite/patologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço/patologia , Variações Dependentes do Observador , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto Jovem
20.
Invest Radiol ; 48(12): 851-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23907104

RESUMO

OBJECTIVES: The purpose of the study was to compare the performance of late iodine-enhancement (LIE) dual-energy computed tomography (DECT) linear blending and selective myocardial iodine mapping for the detection of chronic myocardial infarction (CMI) with late gadolinium-enhancement (LGE) 3-T magnetic resonance imaging. MATERIALS AND METHODS: This study was approved by the institutional review board, and the patients gave informed consent. A total of 20 patients with a history of CMI underwent cardiac LIE-DECT and LGE-MRI. Images of the LIE-DECT were reconstructed as 100 kilovolt (peak) (kV[p]), 140 kV(p), and weighted-average (WA; linear blending) images from low- and high-kilovoltage peak data using 3 different weighting factors (0.8, 0.6, 0.3). Additional color-coded myocardial iodine distribution maps were calculated. The images were reviewed for the presence of late enhancement, transmural extent, signal characteristics, infarct volume, and subjective image quality. RESULTS: Segmental analysis of LIE-DECT data from 100 kV(p), WA of 0.8, and WA of 0.6 showed identical results for the identification of CMI (89% sensitivity, 98% specificity, 96% accuracy) and correctly identified all segments with transmural scarring detected through LGE-MRI. Weighted average of 0.6 received the best subjective image quality rating (15/20 votes) and average measured infarct size correlated best with LGE-MRI (5.7% difference). In comparison with LGE-MRI, iodine distribution maps were susceptible to false-positive and false-negative findings (52% sensitivity, 88% specificity, 81% accuracy), overestimating quantity of transmural scars by 78% while underestimating infarct volume by 55%. CONCLUSIONS: Late iodine enhancement cardiac dual-energy computed tomography correlates well with LGE-MRI for detecting CMI, whereas iodine distribution analysis provides inferior accuracy. Linear blending further improves image quality and enables more precise estimation of scar volume.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Iopamidol/análogos & derivados , Imageamento por Ressonância Magnética/métodos , Meglumina , Infarto do Miocárdio/diagnóstico , Compostos Organometálicos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Doença Crônica , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Iopamidol/administração & dosagem , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...